A critical-mode (CRM) operation has recently been used for low-to-medium power-level power factor correction (PFC) boost converter circuit. In theory, this circuit provides very good power factor and little distortion. However, in a real circuit, the input current of such operation suffers from significant input current distortion. In this paper, the phenomenon of input current distortion was analyzed, and the cause was traced to the parasitic capacitance of the MOSFET switch. An on-time adjustment control scheme, based on rigorous mathematical analysis, was proposed to overcome this problem. In addition, zero voltage switching (ZVS) operation was incorporated into this new scheme. An implementation of the proposed strategy was also presented. Simulations were conducted to verify the validity of the proposed scheme.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.