The fundamental and durable structures of induction motor, as well as their low manufacturing cost, make them popular components in a wide range of current applications. Providing a safety net for employees is a must-have for businesses. This project’s motivation for improvement is to provide industrial motors, lift motors, pumps, and so on with safety. An induction motor’s primary goal is to protect it from problems, such as single phasing and overheating, as well as other issues. Providing industrial motors, pumps, lift motors, and other similar devices with security is a major motivation behind the emergence of this issue. Any of the three phases missing or the motor temperature above the predetermined threshold causes the motor to stop instantly. Three one-stage transformers are connected to a three-phase power supply in the system. Power will be cut to the transformer circuit if any phase is available. Motors can be turned off by relays sending a signal to the four-pole contactor. As a result, the motor’s three-phase power supply has been cut off. Temperature readings are taken from a thermistor (DHT22) that is attached to the motor. At higher temperatures, the three-phase supply will be cut off by a four-pole contactor, and the motor will shut off. This manuscript resolves the uses transformers to solve the problem of single phasing. Also, our project addresses the issue by using microcontroller. It senses all the three phases and decides whether to supply power to induction motor or to disconnect. It deals with the temperature problem, and it uses a thermistor to disconnect the circuitry, whereas in our project, a microcontroller senses the overwhelming temperature and acts accordingly, i.e., give a signal and then move towards disconnection.
<p class="IEEEAbtract"><span lang="EN-US">To make an electrical system reliable and cost-effective, its protection coordination is crucial. Protection coordination is a study to determine the trip settings of protective devices. This research proposes protection coordination for Mehran University of Engineering and Technology, Jamshoro, Sindh. This study includes the coordination of relays connected at each department to the main relay connected with the main vacuum circuit breakers (VCB) by using the time characteristic curves (TCC) and time delay setting of relays using ETAP software. This method is used for the trip of a particular circuit breaker at a proper time. Hence, if a fault occurs in any department only that department will be disconnected, and the rest of the departments will remain in a working condition. This study helps to maintain the system’s high reliability.</span></p>
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.