The authors describe a modified technique for scleral buckling by which a wide retinal tear can be closed with a relatively narrow buckle. An incomplete cut on the silicone sponge can be made so that the halves are connected to each other by a narrow strip of material and opened like a book when buckling. Using this open-book technique, silicone sponges can be used to close horseshoe-shaped retinal tears of one to two times the width of available silicone sponges. This technique was used in four eyes with excellent anatomical results, and no complications could be attributed to the surgical technique. This technique provides an alternative treatment strategy for retinal detachment with relatively wide retinal tears.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.