Background:The clinical efficacy of dopamine D 2 receptor antagonism on the psychotic symptoms of schizophrenia has been widely demonstrated. However, most in vivo imaging studies have not been able to detect significant changes in striatal D 2 receptors in schizophrenia. On the other hand, a number of studies have reported abnormalities in the cerebral cortex of schizophrenia. The aim of this study was to examine the extrastriatal D 2 receptors of patients with schizophrenia.Methods: Eleven drug-naive male patients with schizophrenia were examined with positron emission tomography using carbon 11-labeled FLB 457. Symptoms were assessed using the Brief Psychiatric Rating Scale. Eighteen healthy controls were used for comparison. Regionof-interest analysis was performed using the reference tissue method, and binding potential (BP) was used for the index of dopamine D 2 receptor binding.Results: The BP value was significantly lower, by about 12.5%, in the anterior cingulate cortex in drug-naive patients with schizophrenia than in healthy controls. A significant negative correlation was observed between BP in the anterior cingulate cortex and the positive symptom score on Brief Psychiatric Rating Scale.
Conclusions:The lower BP values indicate fewer D 2 receptors in the anterior cingulate cortex in patients with schizophrenia. Alterations in D 2 receptor function in the extrastriatal region may underlie the positive symptoms of schizophrenia.
Based on 5-HTT occupancy, 40 mg and more of duloxetine was needed to attain 80% occupancy, and 60 mg of duloxetine could maintain a high level of 5-HTT occupancy with a once-a-day administration schedule.
We have developed a prototype 256-slice CT-scanner for four-dimensional (4D) imaging that employs continuous rotations of a cone-beam. Since a cone-beam scan along a circular orbit does not collect a complete set of data to make an exact reconstruction of a volume [three-dimensional (3D) image], it might cause disadvantages or artifacts. To examine effects of the cone-beam data collection on image quality, we have evaluated physical performance of the prototype 256-slice CT-scanner with 0.5 mm slices and compared it to that of a 16-slice CT-scanner with 0.75 mm slices. As a result, we found that image noise, uniformity, and high contrast detectability were independent of z coordinate. A Feldkamp artifact was observed in distortion measurements. Full width at half maximum (FWHM) of slice sensitivity profiles (SSP) increased with z coordinate though it seemed to be caused by other reasons than incompleteness of data. With regard to low contrast detectability, smaller objects were detected more clearly at the midplane (z = 0 mm) than at z = 40 mm, though circular-band like artifacts affected detection. The comparison between the 16-slice and the 256-slice scanners showed better performance for the 16-slice scanner regarding the SSP, low contrast detectability, and distortion. The inferiorities of the 256-slice scanner in other than distortion measurement (Feldkamp artifact) seemed to be partly caused by the prototype nature of the scanner and should be improved in the future scanner. The image noise, uniformity, and high contrast detectability were almost identical for both CTs. The 256-slice scanner was superior to the 16-slice scanner regarding the PSF, though it was caused by the smaller transverse beam width of the 256-slice scanner. In order to compare both scanners comprehensively in terms of exposure dose, noise, slice thickness, and transverse spatial resolution, K=Dsigma2ha3 was calculated, where D was exposure dose (CT dose index), sigma was magnitude of noise, h was slice thickness (FWHM of SSP), and a was transverse spatial resolution (FWHM of PSF). The results showed that the K value was 25% larger for the 16-slice scanner, and that the 256-slice scanner was 1.25 times more effective than the 16-slice scanner at the midplane. The superiority in K value for the 256-slice scanner might be partly caused by decrease of wasted exposure with a wide-angle cone-beam scan. In spite of the several problems of the 256-slice scanner, it took a volume data approximately 1.0 mm (transverse) x 1.3 mm (longitudinal) resolution for a wide field of view (approximately 100 mm long) along the zeta axis in a 1 s scan if resolution was defined by the FWHM of the PSF or the SSP, which should be very useful to take dynamic 3D (4D) images of moving organs.
Thallium tomography with ATP is feasible and has a diagnostic value similar to that with adenosine for detecting coronary artery disease. In addition, it may have fewer side effects than adenosine myocardial tomography.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.