Diseases associated with viruses also found in environmental samples cause major health problems in developing countries. Little is known about the frequency and pattern of viral contamination of drinking water sources in these resource-poor settings. We established a method to analyze 10 liters of water from drinking water sources in a rural area of Benin for the presence of adenoviruses and rotaviruses. Overall, 541 samples from 287 drinking water sources were tested. A total of 12.9% of the sources were positive for adenoviruses and 2.1% of the sources were positive for rotaviruses at least once. Due to the temporary nature of viral contamination in drinking water sources, the probability of virus detection increased with the number of samples taken at one test site over time. No seasonal pattern for viral contaminations was found after samples obtained during the dry and wet seasons were compared. Overall, 3 of 15 surface water samples (20%) and 35 of 247 wells (14.2%) but also 2 of 25 pumps (8%) tested positive for adenoviruses or rotaviruses. The presence of latrines within a radius of 50 m in the vicinity of pumps or wells was identified as being a risk factor for virus detection. In summary, viral contamination was correlated with the presence of latrines in the vicinity of drinking water sources, indicating the importance of appropriate decision support systems in these socioeconomic prospering regions.
a b s t r a c tWithin this article, we report the characterization and organic vapor sensing properties of Langmuir-Blodgett (LB) thin films of calix[8]arenes. Surface pressure-area isotherms show that very stable monolayers are formed at the air-water interface. The LB film could be deposited onto different substrates which allowed the films to be characterized by UV, quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and atomic force microscopy (AFM). The results indicate that good quality, uniform LB films can be prepared with transfer ratios of over 0.95. QCM results showed that the deposited mass of calix[8]arene monolayer onto a quartz crystal decreased from 693 to 204 ng as the number of layers is increased. AFM studies showed a smooth, and void free surface morphology with a rms value of 1.202 nm. The sensing abilities of this LB film towards the development of room temperature organic vapor sensing devices are also studied. Responses of the LB films to various vapors are fast, large, and reversible. It was found that the obtained LB film is significantly more sensitive to chloroform than other vapors. It can be concluded that this molecule could have a potential application in the research area of room temperature vapor sensing devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.