Cryopreservation of PBSCs at a dose of 2×10(8) cells/mL did not affect the recovery rate of viable cells or the hematopoietic recovery of autologous stem cell transplant patients.
Introduction: Efficient laboratory services are the basis of modern health systems. Scientific innovations have contributed to substantial improvements in the laboratory environment, but errors still persist. These errors are classified as pre-analytical, analytical and postanalytical, according to the time of occurrence. Objective: To evaluate the frequency of pre-analytical errors in the clinical laboratory service of a military hospital. Methods: A total of 329,582 tests were performed in the clinical laboratory of Hospital Naval Marcílio Dias (HNMD) from August to October 2012, and pre-analytical errors were documented. Results: The most frequent cause of the observed pre-analytical errors was hemolysis (27.54%), followed by samples not received (25.43%) and insufficient sample volume (18.49%). The samples from the Integrated Home Care Service (SIAD) showed the highest frequency of errors (3.38%), followed by those from the inpatient (0.76%) and the outpatient departments (0.21%). Conclusion: Our study demonstrates the importance of managing laboratory pre-analytical quality in order to ensure service excellence.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.