Background: Administration of a gadolinium-based contrast material is widely considered obligatory for follow-up imaging of patients with multiple sclerosis (MS). However, advances in MRI have substantially improved the sensitivity for detecting new or enlarged lesions in MS. Purpose: To investigate whether the use of contrast material has an effect on the detection of new or enlarged MS lesions and, consequently, the assessment of interval progression. Materials and Methods: In this retrospective study based on a local prospective observational cohort, 507 follow-up MR images obtained in 359 patients with MS (mean age, 38.2 years 6 10.3; 246 women, 113 men) were evaluated. With use of subtraction maps, nonenhanced images (double inversion recovery [DIR], fluid-attenuated inversion recovery [FLAIR]) and contrast material-enhanced (gadoterate meglumine, 0.1 mmol/kg) T1-weighted images were separately assessed for new or enlarged lesions in independent readings by two readers blinded to each other's findings and to clinical information. Primary outcome was the percentage of new or enlarged lesions detected only on contrast-enhanced T1-weighted images and the assessment of interval progression. Interval progression was defined as at least one new or unequivocally enlarged lesion on follow-up MR images. Results: Of 507 follow-up images, 264 showed interval progression, with a total of 1992 new or enlarged and 207 contrastenhancing lesions. Four of these lesions (on three MR images) were retrospectively detected on only the nonenhanced images, corresponding to 1.9% (four of 207) of the enhancing and 0.2% (four of 1992) of all new or enlarged lesions. Nine enhancing lesions were not detected on FLAIR-based subtraction maps (nine of 1442, 0.6%). In none of the 507 images did the contrast-enhanced sequences reveal interval progression that was missed in the readouts of the nonenhanced sequences, with use of either DIR-or FLAIR-based subtraction maps. Interrater agreement was high for all three measures, with intraclass correlation coefficients of 0.91 with FLAIR, 0.94 with DIR, and 0.99 with contrast-enhanced T1-weighted imaging. Conclusion: At 3.0 T, use of a gadolinium-based contrast agent at follow-up MRI did not change the diagnosis of interval disease progression in patients with multiple sclerosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.