This study presents impingement cooling from a flat plate by multiple asymmetric jets. Such jets are discharged through blunt-edge inline orifice holes with a thickness-to-diameter ratio of t/Dj = 0.5 and a jet-to-jet spacing of T/Dj = 4.0, at the Reynolds number of 20,000. Firstly, fluidic features are established both in free exit and with impingement, at varying short target spacing (e.g., H/Dj = 4.0). Secondly, thermal characteristics of the jet impingement are elucidated. Results demonstrate that, due to a skewed incidence of the coolant stream upstream of concave orifice holes, the resulting multiple orifice jets are asymmetric and skewed relative to the orifice axis. These results mimic multiple fluidically inclined jets. However, asymmetric entrainment that takes place causes faster mixing with the surrounding fluid at rest as well as faster decay of momentum. This shows more effective cooling from a flat plate for the relatively short H/Dj range than conventional symmetric orifice and nozzle jets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.