PurposeTo compare the tear film lipid layer thickness (LLT) between patients with incomplete nasolacrimal duct obstruction (NLDO) and normal controls and to analyze the changes in tear film LLT and blinking pattern after silicone tube intubation in NLDO patients.MethodsWe reviewed the medical records of 68 eyes in 52 incomplete NLDO patients who underwent silicone tube intubation from January 2017 to July 2017. The LLT, blinking pattern, and Meibomian gland image were measured with the LipiView II ocular surface interferometer. The Meibomian gland drop-out ratio was measured using the polygon selection tool in the Image J program. Tear meniscus height, which is the other lacrimal indicator, was assessed with spectral-domain optical coherence tomography.ResultsTear meniscus height was significantly decreased after silicone tube intubation (p < 0.01). Preoperative minimum, maximum, and average LLT values were 62.4 ± 24.0, 86.7 ± 17.9, and 71.7 ± 23.3 nm, respectively. Significant changes in the minimum, maximum, and average LLT (74.8 ± 23.6, 98.8 ± 11.0, and 91.6 ± 16.1 nm, respectively) were observed after silicone tube intubation (p < 0.001, p = 0.001, and p < 0.001). The partial blinking/total blinking ratio in 20 seconds and the Meibomian gland drop-out ratio showed no significant change after silicone tube intubation.ConclusionsOverall, the LLT was increased after silicone tube intubation. Silicone tube intubation may be helpful in maintaining LLT with a normalized of amount of tears.
Purpose:We evaluated the clinical efficacy of lacrimal endoscopy-assisted silicone tube intubation in patients with a nasolacrimal duct obstruction. Methods: We conducted a retrospective chart review of 86 eyes of 67 patients who underwent lacrimal endoscopy (RUIDO fiberscope; Fibertechco, Tokyo, Japan)-assisted silicone tube intubation from December 2014 to March 2017. We compared clinical characteristics, irrigation test results, and dacryocystographic and lacrimal endoscopic findings, and analyzed factors related to surgical success. Results: In total, 86 eyes of 67 patients underwent lacrimal endoscopy-assisted silicone tube intubation. The success rate was 87.2%. There was a significantly lower preoperative tear meniscus height (420.5 ± 198.1 μm vs. 639.0 ± 224.3 μm, p < 0.001). In the surgically successful group, narrowing was frequently observed (29.0% vs. 0%, p = 0.030). Dacryolith findings were associated with surgical failure (10% vs. 29%, p = 0.043). Conclusions: Lacrimal endoscopy-assisted silicone tube intubation is considered an effective and successful operative procedure and enables the observation of real-time findings inside the lacrimal drainage passage for the treatment of pathological lesions. Narrowing observed during lacrimal endoscopy indicated successful treatment as opposed to dacryolith findings, which were associated with a failed outcome. J Korean Ophthalmol Soc 2018;59(6):582-588
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.