TiO2 nanotube arrays were successfully synthesized by the anodization method of Ti foils in electrolyte containing the mixtures of ethylene glycol (EG), ammonium fluoride (0.3 wt % NH4F) and deionized water (2 Vol % H2O). A constant dc power supply at 50 V was used anodization process with different anodizing times. The resultant samples were annealed at 450 °C for 2 h. TiO2 nanotube arrays were studied by X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The prepared TiO2 NTs has diameter in 50-200 nm. The minimum of diameter TiO2 nanotube arrays was approximately 50 nm for 1 h of anodization process.
We describe the development of apparatus for measuring of electrical conductivity and Seebeck coefficient with high precision from 85 K to 1,200 K. Electrical resistance was measured by means of four-point probe method as a function of temperature. The temperature below 400 K was measured by using type T thermocouple in vacuum system was used and from 400 to 1,200 was measured by using Type S was applied for temperature between 400 and 1200 Kelvin in an inert gas system. With the dimensions of the specimen, the electrical resistivity (ρT) can be obtained in the unit of microohm-centimeter (μΩ-cm) and be written in polynomial, ρT=-0.3191+6.8×10-3T-6.0×10-7 T2+8.0×10-10T3. The electrical conductivity can be obtained by taking inversion of the electrical resistivity. Seebeck coefficient (αT ) can be calculated in microvolt per Kelvin as follows: αT=1.9653-1.49×10-2T+9.0×10-5T2-2.0×10-7T3+2.0×10-10T4-1.0×10-13T5+3.0×10-17T6 , when T is temperature in K. The Seebeck coefficient data was compared with X-ray diffraction (XRD) and X-ray fluorescence (XRF) of the specimen. The result showed that our developrd apparatus yields the same as standard method when copper with purity greater than 99 percent was employed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.