This study investigated the in vivo 6DOF knee kinematics and tibiofemoral contact location after total knee arthroplasty using a conventional and a high flexion cruciate retaining component (15 NexGen CR, 11 NexGen CR-Flex). Each patient performed a single-leg lunge while being imaged by a dual fluoroscopic imaging system. Data were analyzed at hyperextension, 0 degrees to 90 degrees in 15 degrees intervals, and at maximum flexion. The average maximum weight-bearing flexion for all the CR patients was 110.1 degrees +/- 13.4 degrees , and for all the CR-Flex patients was 108.2 degrees +/- 13.2 degrees . No difference was seen in the maximum flexion achieved by the patients, and the kinematics demonstrated by the groups was similar. However, at high flexion, the tibiofemoral articulating surfaces were more conforming in the CR-Flex design than the CR design, suggesting that the use of the high flexion component improved the tibiofemoral contact environment at high flexion in patients who could achieve high flexion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.