BackgroundThe placement of an implantable cardioverter defibrillator (ICD) has become routine practice to protect high risk patients from sudden cardiac death. However, implantation-related myocardial micro-damage and its relation to different implantation strategies are poorly characterized.MethodsA total of 194 ICD recipients (64±12 years, 83% male, 95% primary prevention of sudden cardiac death, 35% cardiac resynchronization therapy) were randomly assigned to one of three implantation strategies: (1) ICD implantation without any defibrillation threshold (DFT) testing, (2) estimation of the DFT without arrhythmia induction (modified “upper limit of vulnerability (ULV) testing”) or (3) traditional safety margin testing including ventricular arrhythmia induction. High-sensitive Troponin T (hsTnT) levels were determined prior to the implantation and 6 hours after.ResultsAll three groups showed a postoperative increase of hsTnT. The mean delta was 0.031±0.032 ng/ml for patients without DFT testing, 0.080±0.067 ng/ml for the modified ULV-testing and 0.064±0.056 ng/ml for patients with traditional safety margin testing. Delta hsTnT was significantly larger in both of the groups with intraoperative ICD testing compared to the non-testing strategy (p≤0.001 each). There was no statistical difference in delta hsTnT between the two groups with intraoperative ICD testing (p = 0.179).ConclusionHigh-sensitive Troponin T release during ICD implantation is significantly higher in patients with intraoperative ICD testing using shock applications compared to those without testing. Shock applications, with or without arrhythmia induction, did not result in a significantly different delta hsTnT. Hence, the ICD shock itself and not ventricular fibrillation seems to cause myocardial micro-damage.Trial RegistrationClinicalTrials.gov NCT01230086
Objective. Despite the use of anticoagulation during left atrial (LA) ablation procedures, ischemic cerebrovascular accidents (CVAs) are recognized as a serious complication. Heparin is usually given after safe transseptal access has been obtained, resulting in a short unprotected dwell time of catheters within the LA, which may account for CVAs. We investigated the frequency of CVAs and LA thrombus formation as detected by intracardiac ultrasound (ICE) depending on the timing of heparin administration. Methods and Results. Sixty LA ablation procedures with the use of ICE were performed in 55 patients. Patients were grouped by heparin administration after (Group I, n = 13) and before (Group II, n = 47) transseptal access. Group I patients were younger (56.6 ± 13.7 versus 65.9 ± 9.9 years, P = .01); other clinical and echocardiographic characteristics did not differ between groups. Early thrombus formation was observed in 2 (15.4%) of group I patients as compared to 0% of group II patients (P = .04). One CVA (2.1%) occurred in one group II patient without prior thrombus detection, and none occurred in group I patients (P = ns). Conclusion. Early administration of heparin reduces the risk of early intracardiac thrombus formation during LA ablation procedures. This did not result in reduced rate of CVAs.
AimsDuty-cycled radiofrequency ablation (RFA) has been used for atrial fibrillation (AF) for around 5 years, but large-scale data are scarce. The purpose of this survey was to report the outcome of the technique.Methods and resultsA survey was conducted among 20 centres from seven European countries including 2748 patients (2128 with paroxysmal and 620 with persistent AF). In paroxysmal AF an overall success rate of 82% [median 80%, interquartile range (IQR) 74–90%], a first procedure success rate of 72% [median 74% (IQR 59–83%)], and a success of antiarrhythmic medication of 59% [median 60% (IQR 39–72%)] was reported. In persistent AF, success rates were significantly lower with 70% [median 74% (IQR 60–92%)]; P = 0.05) as well as the first procedure success rate of 58% [median 55% (IQR 47–81%)]; P = 0.001). The overall success rate was similar among higher and lower volume centres and were not dependent on the duration of experience with duty-cycled RFA (r = −0.08, P = 0.72). Complications were observed in 108 (3.9%) patients, including 31 (1.1%) with symptomatic transient ischaemic attack or stroke, which had the same incidence in paroxysmal and persistent AF (1.1 vs. 1.1%) and was unrelated to the case load (r = 0.24, P = 0.15), bridging anticoagulation to low molecular heparin, routine administration of heparin over the long sheath, whether a transoesophageal echocardiogram was performed in every patient or not and average procedure times.ConclusionDuty-cycled RFA has a self-reported success and complication rate similar to conventional RFA. After technical modifications a prospective registry with controlled data monitoring should be conducted to assess outcome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.