Background: Cancer antigen CA125 is known as a valuable marker for the management of ovarian cancer. Methods: The analytical and clinical performance of the Access OV Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA125 on the Elecsys System (Roche Diagnostics). Results: Total imprecision (%CV) of the OV Monitor ranged between 3.1% and 8.8%, and inter-laboratory reproducibility between 4.7% and 5.0%. Linearity upon dilution showed a mean recovery of 100% (SDq8.1%). Endogenous interferents had no influence on OV Monitor levels (mean recoveries: hemoglobin 107%, bilirubin 103%, triglycerides 103%). There was no high-dose hook effect up to 27,193 kU/L. Clinical performance investigated in sera from 1811 individuals showed a good correlation between the Access OV Monitor and Elecsys CA125 (Rs0.982, slopes0.921, interceptsq1.951). OV Monitor serum levels were low in healthy individuals (ns267, medians9.7 kU/L, 95th percentiles30.8 kU/L), higher in individuals with various benign diseases (ns549, medianss10.9-16.4 kU/L, 95th percentiless44.2-355 kU/L) and even higher in individuals suffering from various cancers (ns995, medianss12.4-445
Background: Cancer antigen CA15-3 antigen is known as a valuable marker for the management of breast cancer.
Methods:The analytical and clinical performance of the Access ᮋ BR Monitor Immunoassay System (Beckman Coulter) was evaluated at five different European sites and compared with a reference system, defined as CA15-3 on the Elecsys ᮋ System (Roche Diagnostics). Results: Total imprecision (%CV) of the BR Monitor ranged between 5.5% and 11.7%, and inter-laboratory reproducibility between 3.4% and 5.1%. Linearity upon dilution showed a mean recovery of 98.5% (SD"9.1%). Endogenous interferents had no influence on BR Monitor levels (mean recoveries: hemoglobin 112%, bilirubin 111%, triglycerides 108%). There was no high-dose hook effect up to 13,540 kU/L. Clinical performance investigated in sera from 1811 individuals showed a general correlation between the Access BR Monitor and Elecsys CA15-3 (Rs0.797), with a slope of 1.383. CA15-3 serum levels, as measured by the BR Monitor, were low in healthy individuals (ns267, medians11.9 kU/L, 95th percentiles23.5 kU/L), higher in individuals with various benign diseases (ns549, medianss11.3-15.6 kU/L, 95th percentiless21.6-54.6 kU/L) and even higher in
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.