From a set of weakly potent lead compounds, using in silico screening and small library synthesis, a series of 2-alkyl-3-aryl-3-alkoxyisoindolinones has been identified as inhibitors of the MDM2-p53 interaction. Two of the most potent compounds, 2-benzyl-3-(4-chlorophenyl)-3-(3-hydroxypropoxy)-2,3-dihydroisoindol-1-one (76; IC(50) = 15.9 +/- 0.8 microM) and 3-(4-chlorophenyl)-3-(4-hydroxy-3,5-dimethoxybenzyloxy)-2-propyl-2,3-dihydroisoindol-1-one (79; IC(50) = 5.3 +/- 0.9 microM), induced p53-dependent gene transcription, in a dose-dependent manner, in the MDM2 amplified, SJSA human sarcoma cell line.
The design, synthesis and evaluation of 24 isoindolinones as potential inhibitors of the MDM2-p53 interaction is described. The most potent inhibitor NU8231 (ELISA: IC 50 = 5.3 ± 0.9 µM) displays cellular activity in human SJSA cells.
BackgroundThe use of point-of-care ultrasonography (POC US) in paediatrics is increasing. This study investigated the diagnostic accuracy of POC US in children accessing the emergency department (ED) when performed by paediatricians under the remote guidance of radiologists (TELE POC).MethodsChildren aged 0 to 18 years accessing the ED of a third level research hospital with eight possible clinical scenarios and without emergency/severity signs at the triage underwent three subsequent US tests: by a paediatrician guided remotely by a radiologist (TELE POC); by the same radiologist (UNBLIND RAD); by an independent blinded radiologist (BLIND RAD). Tele-radiology was implemented using low cost “commercial off-the-shelf” (COTS) equipment and open-source software. Data were prospectively collected on predefined templates.ResultsFifty-two children were enrolled, for a total of 170 ultrasound findings. Sensitivity, specificity, positive and negative predictive values of TELE POC were: 93.8, 99.7, 96.8, 99.4 when compared to UNBLIND RAD and 88.2, 99.7, 96.8, 98.7 when compared to BLIND RAD. The inter-observers agreement between the paediatricians and either the unblind or blind radiologist was excellent (k = 0.93). The mean duration of TELE POC was 6.3 minutes (95% CI 4.1 to 8.5). Technical difficulties occurred in two (3.8%) cases. Quality of the transmission was rated as fair, good, very good and excellent in 7.7%, 15.4%, 42.3% and 34.6% of cases respectively, while in no case was it rated as poor.ConclusionsPOC US performed by paediatricians in ED guided via tele-radiology by an expert radiologist (TELE POC) produced reliable and timely diagnoses. Findings of this study, especially for the rarer conditions under evaluation, need further confirmation. Future research should investigate the overall benefits and the cost savings of using tele-ultrasound to perform US “at children’s bedsides”, under remote guidance of expert radiologists.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.