Because coadministration of HOE (at a concentration sufficient to inhibit NHE activity) did not reduce the efficacy of PC in either protocol, we conclude that NHE activity does not contribute to the cardioprotective actions of PC. On the contrary, NHE inhibition during the prolonged ischemic period may enhance the protection afforded by PC.
Over the last 4 months, the novel coronavirus, SARS‐CoV‐2, has caused a significant economic, political, and public health impact on a global scale. The natural history of the disease and surge in the need for invasive ventilation has required the provision of intensive care beds in London to be reallocated. NHS England have proposed the formation of a Pan‐London Emergency Cardiac surgery (PLECS) service to provide urgent and emergency cardiac surgery for the whole of London. In this initial report, we outline our experience of setting up and delivering a pan‐regional service for the delivery of urgent and emergency cardiac surgery with a focus on maintaining a COVID‐free in‐hospital environment. In doing so, we hope that other regions can use this as a starting point in developing their own region‐specific pathways if the spread of coronavirus necessitates similar measures be put in place across the United Kingdom.
Selective laser melting (SLM) has previously been shown to be a viable method for fabricating biomedical implants; however, the surface chemistry of SLM fabricated parts is poorly understood. In this study, X-ray photoelectron spectroscopy (XPS) was used to determine the surface chemistries of (a) SLM as-fabricated (SLM-AF) Ti6Al4V and (b) SLM fabricated and mechanically polished (SLM-MP) Ti6Al4V samples and compared with (c) traditionally manufactured (forged) and mechanically polished Ti6Al4V samples. The SLM-AF surface was observed to be porous with an average surface roughness (Ra) of 17.6±3.7μm. The surface chemistry of the SLM-AF was significantly different to the FGD-MP surface with respect to elemental distribution and their existence on the outermost surface. Sintered particles on the SLM-AF surface were observed to affect depth profiling of the sample due to a shadowing effect during argon ion sputtering. Surface heterogeneity was observed for all three surfaces; however, vanadium was witnessed only on the mechanically polished (SLM-MP and FGD-MP) surfaces. The direct and indirect 3T3 cell cytotoxicity studies revealed that the cells were viable on the SLM fabricated Ti6Al4V parts. The varied surface chemistry of the SLM-AF and SLM-MP did not influence the cell behaviour.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.