Comparison of continuous versus intermittent (every 12 h bolus) infusion of a high-purity Factor VIII concentrate in 12 severe hemophilia A patients undergoing surgical procedures indicated that a higher (50 u/dl versus 35 u/dl) minimal plasma level was seen with the same amount of product when given continuously. A continuous VIII concentrate infusion of 2 u/kg/h produces a mean VIIIc level of about 50 u/dl or, alternatively, about 0.04 u/kg/h raises the VIIIc level by 1 u/dl (1%). None of the patients showed any abnormal bleeding. Higher plasma levels of VIIIc were noted by the two-stage VIIIc assay than by the one-stage VIIIc assay. Fibrinogen levels were normal or only slightly elevated, and the monomer test was consistently negative.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.