Treatment of extra-articular distal humerus shaft fractures with plating techniques is often difficult, as traditional centrally located posterior plates often encroach on the olecranon fossa, limiting distal osseous fixation. The use of a modified Synthes Lateral Tibial Head Buttress Plate (Synthes, Paoli, PA) allows for a centrally placed posterior plating of the humeral shaft that angles anatomically along the lateral column to treat far distal humeral shaft fractures. Fifteen patients treated in this manner were followed to radiographic and clinical union. There were no cases of instrumentation failure or loss of reduction.
Intramedullary strut allograft insertion combined with fixed-angle plating is an effective technique for treating viable nonunions of the proximal humerus and was successful in achieving union in 94% of our patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.