Background and Aims:The aim was to compare duration of postoperative analgesia with addition of clonidine to bupivacaine in bilateral transversus abdominis plane (TAP) block after lower segment cesarean section (LSCS).Material and Methods:One hundred American Society of Anesthesiologists (ASA) grade I and II pregnant patients undergoing LSCS under spinal anesthesia were randomly divided to receive either 20 ml bupivacaine 0.25% (Group B; n = 50) or 20 ml bupivacaine+1ug/kg clonidine bilaterally (Group BC; n = 50) in TAP block in a double-blind fashion. The total duration of analgesia, patient satisfaction score, total requirement of analgesics in the first 24 h, and the side effects of clonidine such as sedation, dryness of mouth, hypotension, and bradycardia were observed. P < 0.05 was taken as significant.Results:In 99 patients analyzed, TAP block failed in five patients. Duration of analgesia was significantly longer in Group BC (17.8 ± 3.7 h) compared to Group B (7.3 ± 1.2 h; P < 0.01). Mean consumption of diclofenac was 150 mg and 65.4 mg in Groups B and BC (P < 0.01), respectively. All patients in Group BC were extremely satisfied (P < 0.01) while those in Group B were satisfied. Thirteen patients (28%) in Group BC were sedated but arousable (P = 0.01) compared to none in Group B. In Group BC, 19 patients complained of dry mouth compared to 13 in Group B (P = 0.121). None of the patients experienced hypotension or bradycardia.Conclusion:Addition of clonidine 1 μg/kg to 20 ml bupivacaine 0.25% in TAP block bilaterally for cesarean section significantly increases the duration of postoperative analgesia, decreases postoperative analgesic requirement, and increases maternal comfort compared to 20 ml of bupivacaine 0.25% alone.
Central venous catheter (CVC) placement is not only restricted to Intensive Care Units and operation theaters but its horizon has also expanded to the bedside placements. Meticulous care and aids such as ultrasound and fluoroscopy dramatically increase the successful placement of needles, guidewires, and catheters, but still a large number of catheter misplacements can occur. The formation of a loop in CVC is a rare complication occurring mostly during right-sided catheterization. We report a rare complication of coiling of left subclavian CVC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.