Abstract-We present a method of making low loss split-ring resonators for microfluidic sensing at microwave frequencies using silver coated copper wire. We show that a simple geometric modification and the use of square cross-section wire give greater electric field confinement in the capacitive region of the resonant sensor. We use a combination of theoretical analysis, finite element simulations and empirical measurements to demonstrate the subsequent increases in the sensitivity of these split ring resonators for complex permittivity measurements of some common solvents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.