Background/Aims: Mucosal incision-assisted biopsy (MIAB) for tissue acquisition (TA) from subepithelial lesions (SELs) is emerging as an alternative to endoscopic ultrasound (EUS)-guided TA. Only a limited number of studies compared the diagnostic utility of MIAB and EUS for upper gastrointestinal (GI) SELs; therefore, we conducted this systematic review and meta-analysis.Methods: A comprehensive literature search from January 2020 to January 2022 was performed to compare the diagnostic accuracy and safety of MIAB and EUS-guided TA for upper GI SELs.Results: Seven studies were included in this meta-analysis. The pooled technical success rate (risk ratio [RR], 0.96; 95% confidence interval [CI], 0.89–1.04) and procedural time (mean difference=–4.53 seconds; 95% CI, –22.38 to 13.31] were comparable between both the groups. The overall chance of obtaining a positive diagnostic yield was lower with EUS than with MIAB for all lesions (RR, 0.83; 95% CI, 0.71–0.98) but comparable when using a fine-needle biopsy needle (RR, 0.93; 95% CI, 0.83–1.04). The positive diagnostic yield of MIAB was higher for lesions <20 mm (RR, 0.75; 95% CI, 0.63–0.89). Six studies reported no adverse events.Conclusions: MIAB can be considered an effective alternative to EUS-guided TA for upper GI SELs without an increased risk of adverse events.
Background: Endoscopic ultrasound (EUS)-guided tissue acquisition is the preferred modality for diagnosing pancreatic lesions and mediastinal and abdominal lymph nodes. Rapid on-site cytologic evaluation improves the diagnostic outcome of EUS-guided fine-needle aspiration (FNA) but is unavailable at many centers.Alternatively, macroscopic on-site evaluation (MOSE) may improve the diagnostic outcome of EUS-FNA, but data are limited. Hence, the present study was conducted to assess the efficacy of MOSE in improving adequacy and accuracy.Methods: We retrospectively analyzed data of consecutive patients with pancreatic or lymph nodal lesions undergoing EUS-guided FNA at a tertiary care center from December 2020 to December 2022. The study's primary outcomes were adequacy and diagnostic accuracy of the EUS-guided tissue acquisition, with secondary analysis of predictors of adequacy and accuracy.Results: Data from 124 patients (44.4% male, median age: 54 years) who underwent EUS-FNA were included in the present analysis. The presence of macroscopic visible core (MVC) on MOSE was reported in 93/124 (75%) cases. An adequate sample for histopathological or cytological examination was obtained in 110/124 (88.7%) cases, while the diagnostic accuracy was 85.5%. On multivariate analysis, the absence of MVC on MOSE was found to be the independent negative predictor of both adequacy (OR 0.092, 95% CI: 0.024-0.349) and accuracy (OR 0.175, 95% CI: 0.057-0.536).
Conclusion:The presence of MVC on MOSE can be an indicator of specimen adequacy and can improve the diagnostic yield of EUS-FNA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.