Purpose In this study, it was aimed to evaluate the functionality to deliver different prescription dose except 20 Gy for the Xoft Axxent Ebt (electronic Brachytherapy) system and analyzing the system in terms of radiation dosimetry in water and 0.9% isotonic Sodium Chloride (NaCl) solution. Materials and methods In the Xoft Axxent eBT, different prescription dose in single fraction were calculated for different balloon applicator volumes based on source position and irradiation times. EBT-XD Gafchromic film was calibrated at 6MV photon energy. A balloon applicator filled with 0.9% isotonic NaCl solution was used to deliver a radiation dose of 20 Gy, 16 Gy, 10 Gy on the applicator surface. Then the balloon applicator was filled with water and the same measurements were repeated. Finally, the balloon applicator was irradiated by positioning it at different distances in the water phantom to simulate the isodose contour. Results At the time the balloon applicator was filled with water and 0,9% NaCl solution, the difference between the planned dose and the absorbed dose was ~ 2% vs. 15% for 30 cc, ~ 5% vs. 14% for 35 cc and ~ 3,5% vs. 10% for 40 cc respectively. Finally, the absorbed dose at a distance of 1 cm from the applicator surface was measured as 9.63 Gy. Conclusion In this study, it was showed that different prescription dose could be possible to deliver in the Xoft Axxent eBT system based on the standard plan. In addition, the absorbed dose was higher than the planned dose depending on the effective atomic number of NaCl solution comparing to water due to photoelectric effect in low energy photons. By measuring the dose distributions at different distances from the balloon applicator surface, the absorbed dose in tissue equivalent medium was determined and the isodose contours characteristics was simulated.
Purpose This study aims at evaluating the functionality of different dose fractions for the Xoft Axxent electronic brachytherapy (eBT) system and analyzing the system in terms of radiation dosimetry in water. Materials and Methods Different dose fraction schemes for the Xoft Axxent eBT system were calculated for different balloon applicator volumes based on dwell positions and dwell times. EBT-XD Gafchromic film was calibrated at 6MV photon energy and a calibration curve was devised for it which were used for dosimetric measurements. In the first phase, a balloon applicator filled with 0.9% isotonic sodium chloride (NaCl) solution was used for dosimetric measurements with the ability to deliver 20 Gy, 16 Gy, 10 Gy radiation dose in one fraction. Afterward, the balloon applicator was filled with water and the same measurements were performed. Finally, the balloon applicator was irradiated at different distances in the water tank and the simulation of dose distribution in the water was obtained so as to analyze the dose distribution in the tissue. Results At the time the balloon applicator was filled with 0.9% NaCl solution, the absorbed dose was approximately 23 Gy for 30 cc balloon volume, 22.8 Gy for 35 cc and 22 Gy for 40 cc balloon volume. On the other side, when the applicator was filled with water, the absorbed dose is approximately 20.5 Gy for 30 cc, 21 Gy for 35 cc, and 20,7 Gy for 40 cc balloon applicator. As a result, provided the balloon applicator was filled with water, the difference between the planned dose and the absorbed dose was ~ 2% for 30 cc, ~ 5% for 35 cc and ~ 3,5% for 40 cc. Accordingly, the fact that 0.9% NaCl solution caused an increase in the absorbed dose from the photoelectric effect was determine. Finally, the absorbed dose at a distance of 1 cm from the applicator surface was measured as 9.63 Gy which was obtained in accordance with the manufacturer’s criteria. Conclusion Different dose fraction schemes were created in the Xoft Axxent eBT system based on the standard atlas plan. In addition, this study shows that photoelectric effect in low energy photons increases the difference between the planned dose and the absorbed dose depending on the effective atomic number. By measuring the dose distributions at different distances from the balloon applicator surface, the absorbed dose in tissue equivalent medium was determined and the dose distribution characteristics was simulated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.