ImportanceIn patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited.ObjectiveTo report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial.Design, Setting, and ParticipantsSURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021.InterventionPatients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis.Main Outcomes and MeasuresThe prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years.ResultsA total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm2 vs 1.8 [0.6] cm2; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention.Conclusions and RelevanceAmong intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Mixed messages containing contradictory communication components were shown to normal and disturbed adults and children. The overall results revealed that normal adults' evaluations of mixed messages were significantly different from those of disturbed adults and from those of normal and disturbed children. Normal adults appeared to be influenced by all communication components (verbal statement, facial expression, vocal tone, and physical gesture) in mixed messages, whereas the other three subject groups were primarily influenced by the words.
As news migrates to mobile phones, media companies are turning to data visualization to wet readers' appetites for stories they can read at length on their home or work computers. Journalists are trained to write stories, not in statistics or coding, however. The big news organizations have the funds to hire computer graphics experts, but local news organizations need help.
To determine their ability to interpret messages, normal and disturbed children, adolescents, and adults (ns = 10) were shown videotaped statements containing discrepant verbal and nonverbal components and statements containing consistent verbal and nonverbal components. No significant differences were observed between subjects in response to the consistent messages regardless of age or mental status; however, pronounced differences occurred under the condition with discrepant messages. Among normal subjects a developmental shift was observed, i.e., an inverse relation was found between age and reliance upon verbal content. Younger normal subjects relied upon the verbal content of a message in interpretation, while adults relied upon the nonverbal elements. Disturbed subjects regardless of age relied primarily upon the verbal content of the discrepant message.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.