Top-up operation allows SPring-8 to provide highly stable X-ray beams with arbitrary filling patterns. The implementation of top-up operation is described, with a focus on the simultaneous achievement of stability of stored current, beam orbit, purity of an isolated single bunch, and beam injection efficiency. Stored-current fluctuations have been routinely reduced to a level of 10 À3 . Stored-beam oscillation on frequent beam injection, which was originally regarded as the most serious problem, has been successfully suppressed to a sufficiently low level that it never perturbs imaging experiments. Current impurities in nominally empty buckets have been reduced to a level of 10 À9 over more than one week of operation, making possible the measurement of timeresolved spectra using high-current bunches. Finally, excellent injection efficiency, higher than 80%, is routinely obtained, even for small undulator gaps, which is critical for preventing radiation damage to insertion-device magnets and to reduce leakage radiation. The process of achieving highly stabilized top-up operation at SPring-8 and its utility for user experiments are described.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.