A sample pretreatment method based on microporous membrane liquid-liquid extraction (MMLLE) was developed for the subsequent gas chromatographic determination of pesticides in wine. MMLLE provided efficient and selective extraction with enrichment factors in the range 3-13. The gas chromatographic separation was carried out using on-column injection and flame ionization detection. The method was linear, repeatable and sensitive. The limits of quantification were better than 0.006 mg/L for all the analytes except for iprodione (0.37 mg/L). The method was applied to the determination of pesticides in several red wines of different origin.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.