Our findings suggest that the LT PGA/TMC barrier membrane, used in conjunction with an allograft, provides lateral alveolar ridge augmentation comparable to that achieved with other materials without the necessity for bone-graft harvesting or a second procedure to remove the barrier membrane.
Large portion of the domestic bridges are slab bridges reflecting the geographical characteristic of the country, where exists lots of inclines and small winding brooks. Many of the slab bridges are damaged and superannuated as they become obsolete. Deterioration is accelerated when the traffic density becomes large and heavy vehicles pass frequently. A strengthening method for deteriorated slab bridges was studied in this work. The examined net-type strengthening method uses both longitudinal and transverse prestressing for strengthening. In this way, the deflection at the center of the slab can be better controlled, and consequently, the slab is more efficiently strengthened. Three slab specimens were fabricated for the experimental test and subjected to three different loading conditions, and the load bearing capacities and deflections of slabs were examined. Flexural stiffness of slabs increased by 30.7~107.3%, and deflection of slabs decreased by 27.6~52.2% after net-type strengthening. The net-type prestressing is efficient to the strengthening for the center of a slab, and its efficiency is also valid under eccentric loadings. Since extra prestress forces can be added in the future, if necessary, the net-type strengthening system is advantagous for the maintenance and repair of slab bridges.
Holed-Incrementally Prestressed Concrete (H-IPC) girders are designed using the following new design concepts. At first, web openings reduce the self-weight of the girder, and also diffuse prestressing tendon anchorages. The reduced end anchoring forces decrease the web thickness of the end sections. Additionally, precast technology help to improve the quality of concrete and to reduce the construction period at the site. For experimentally verification, two 50 m full-scale H-IPC girders are manufactured with different concrete strength of 55 MPa and 80 MPa. The safety, stiffness, ductility, serviceability and crack development of H-IPC girder are measured and compared with each other for different strengths. Both girders show enough strength to carry live load and good stiffness to satisfy the design criteria. The experimental result shows the advantages of using high strength concrete and adopting precast girder. The test data can be used as a criterion for safety control and maintenance of the H-IPC girder.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.