MR cholangiography coupled with dynamic 3D gradient-echo imaging could not only detect portal vein occlusion, cavernous transformation, and gallbladder varices but is also suitable for delineating associated bile duct abnormalities.
We report a case of acute hemothorax caused by a left internal thoracic artery pseudoaneurysm rupture in a patient with neurofibromatosis type I, which was successfully treated with endovascular coil embolization.
This study indicates that no significant differences were observed in the clinical outcome between coil embolization and surgical clipping techniques in the treatment of aneurysms causing ONP. Coil embolization seems to be more feasible and safe treatment modality for the relief and recovery of oculomotor nerve palsy.
Objective : To assess the feasibility, safety, and effectiveness of the balloon-assisted technique with HyperForm balloon in the endovascular treatment of wide-necked intracranial aneurysms. Methods : A total of 34 patients with 34 wide-necked intracranial aneurysms were treated with endovascular coil embolization using balloonassisted technique with Hyperform balloon. Twenty-nine aneurysms (85.3%) were located in the anterior circulation. The group of patients was comprised of 16 men and 18 women, aged 33 to 72 years (mean : 60.6 years). The size of aneurysms was in the range of 2.0 to 22.0 mm (mean 5.5 mm) and one of neck was 2.0 to 11.9 mm (mean 3.8 mm). The dome to neck ratio was ranged from 0.83 to 1.43 (1.15). Sixteen patients were treated for unruptured aneurysms and the remaining 18 presented with a subarachnoid hemorrhage. Results : In the 34 aneurysms treated by the remodeling technique with HyperForm balloon, immediate angiographic results consisted of total occlusion in 31 cases (91.2%) and partial occlusion in three cases (8.8%). There were five procedure-related complications (14.7%), including two coil protrusions and three thromboembolisms; Except one patient, all were successfully resolved without permanent neurologic deficit. No new bleeding occurred during the follow-up. Twenty patients (59%) underwent angiographic follow-up from 2 to 33 months (mean 9.2 months) after treatment. Focal recanalization with coil compaction of the neck portion was observed in 5 cases (25%). Only one case showed major recanalization and underwent stent-assisted coil embolization.
Conclusion :The balloon-assisted technique with Hyperform balloon is a feasible, safe, and effective endovascular treatment of wide-necked cerebral aneurysms.
KEY WORDS :Intracranial aneurysms˙ Wide-necked aneurysms˙ Endovascular treatment˙ Balloon-assisted technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.