Laparoscopic Nissen fundoplication involves retraction of the gastro-oesophageal junction using a Penrose drain to create a retro-oesophageal window. 1 We describe a latex-free alternative to the Penrose drain for patients with latex allergy. A size 8 or larger latex-free glove is fashioned into a sling, by cutting away all but the index and middle-finger portions (Fig 1). The bridge between these fingers, which normally covers the surgeon's interdigital space, forms the sling apex. This is passed around the distal oesophagus exactly as a Penrose drain and offers a safe, quick, and cost-effective latex-free alternative (Fig 2).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.