SUMMARYIt has been reported that the calculated values of field transient behavior in a synchronous machine differ considerably from the measured values. This discrepancy is caused by the use of equivalent circuit constants in the standardized tests provided by JEC-2130 and IEC-60034-4, in which the mutual leakage reactance between the damper and field windings is not accounted for. The authors have been studying a method for calculating equivalent circuit constants for the accurate simulation of transient behavior including the field winding side, by means of a standstill test with a small-capacity DC power supply (DC decay testing method). The authors have previously presented a calculation method using operational impedances with the field windings opened, shorted, and shorted with an external resistance, obtained by the DC decay test. This paper presents a new method in which the external resistance used in our previous method is no longer needed. Instead, the field winding impedance is determined on the basis of its invariability against slip. The validity of the new method is demonstrated by comparing the calculated and measured values of the armature and field currents during a sudden three-phase short-circuit using 10 kVA/200 V/31.9 A/4 P/50 Hz test machines.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.