The critical heat fluxes (CHFs) of subcooled water flow boiling are systematically measured for the flow velocities (u = 4.0 to 13.3 m/s), the outlet subcoolings (ΔTsub,out = 3 to 129 K) and the outlet pressure (Pout = 800 kPa). The SUS304 test tubes of 3, 6, 9 and 12 mm in inner-diameter, d, and 33, 66, 99 and 133 mm in length, L, respectively for L/d = 11 are used. The CHFs first become lower and then become higher with the increase in subcooling. The CHFs for four different inner-diameters with L/d = 11 measured here become higher with the decrease in the diameter. CHF correlation for the latter increasing regime was given in non-dimensional form against average outlet subcoolings based on the experimental data. The correlation can describe not only the CHFs obtained in this work at the outlet pressure of 800 kPa but also the authors’ published CHFs (1284 points) for the wide range of Pout = 159 kPa to 1 MPa, d = 6, 9 and 12 mm, L = 49, 99 and 149 mm, ΔTsub,out = −4 to 130 K and u = 4.0 to 13.3 m/s within 15% difference for 50 K≤ΔTsub,out≤130 K and within +30 to −10% for 30 K<ΔTsub,out<50 K.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.