Packed-nanofiber solid phase extraction (PFSPE) combined with gas chromatography-flame ionization detector (GC-FID) was developed for the simultaneous determination of five phthalate esters (PAEs) and bisphenol A (BPA) in fruit juice. The PAEs and BPA was concentrated by PFSPE using polystyrene- pyridine (PS-PD) nanofibers as the sorbent, followed determined by GC-FID. Under this modified procedure, satisfied recoveries in fruit juice sample ranging from 81.9% to 109.6% were obtained. And relative standard deviation values (RSD) were ranged from 1.9 % to 9.8% in orange juice sample. The limits of detection (LOD) and the limits of quantification (LOQ) of five PAEs and BPA were ranged from 0.02 μg/mL to 0.30 μg/mL and 0.06 μg/L to 1.10 μg/L, respectively. This established method was successfully applied to detect real fruit juice samples, which were collected in local supermarket. These results demonstrated the applicability of the established PFSPE-based extraction coupled with gas chromatography method for determination of PAEs and BPA in fruit juice products.
A method for the determination of Rhodamine B in sausage was developed and validated. After extraction of Rhodamine B with acetonitrile from foodstuffs, a novel electrospun polymer nanofibers packed micro-column was used for cleaning and concentrating of the analyte in the sample. High performance liquid chromatography with fluorescence detection (HPLC-Flu) was used for the determination of Rhodamine B in the sample. The mobile phase was composed of 3.0 g L-1 phosphate buffer and methanol (3:7, volume ratio), and the pH was adjusted to 7. 0 with orthophosphoric acid. The results showed that the standard curve was linear over the validated concentrations range of 2-500 ng g-1, and the limit of detection (LOD) and the limit of quantitation (LOQ) for Rhodamine B spiked samples was 0. 2 ng g-1 and 0. 7 ng g-1, respectively. The average recoveries of Rhodamine B were 90.4% -94.3% for sausage, and the relative standard deviation of the method was from 1.7% to 3.8%. This proposed method was applied to real sample, and there was no Rhodamine B found in sausage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.