Background: Hematological reference intervals are used for medical decision tools for interpretation of numerical test results. Establishing of hematological interval among newborn babies is very important for the diagnosis of malignancy, anemia, bleeding disorders, and various infections. There is no locally established hematological reference intervals in Ethiopia. Thus the aim of this study is to established locally determined hematological reference interval among full-term newborn babies.Methods: A cross sectional study was conducted from February to May 2019 among 151 apparently healthy full-term newborn babies at Gondar University Hospital. About 3ml of cord blood was obtained for analysis of Hematological parameters and determined by using Sysmex KX-21N (Sysmex Corporation Kobe, Japan) automated analyzer. Median, 2.5th and 97.5th percentiles were computed. Result: Males to female’s ratio was almost equal. All hematological parameter had no statistically significant difference between males and females. The delivery types were not influenced its hematological values. Conclusion: Hematological reference interval was established from full-term newborn babies at University of Gondar hospital and was different from other studies in African and Europeans. Therefore, own determined reference value is very important for the clinicians to correctly diagnosis the patients at health facility levels.
Background: Hematological reference intervals are used for medical decision tools for interpretation of numerical test results. Establishing of hematological interval among newborn babies is very important for the diagnosis of malignancy, anemia, bleeding disorders, and various infections. There is no locally established hematological reference intervals in Ethiopia. Thus, the aim of this study is to established locally determined hematological reference interval among full-term newborns.Methods: A cross sectional study was conducted from February to May 2019 among 151 apparently healthy full-term newborns at Gondar University Hospital. About 3ml of cord blood was obtained for analysis of Hematological parameters and determined by using Sysmex KX-21N (Sysmex Corporation Kobe, Japan) automated analyzer. Median, 2.5th and 97.5th percentiles were computed.Result: Males to female’s ratio was almost equal. All hematological parameter had no statistically significant difference between males and females. The delivery types were not influenced its hematological values. The reference interval of white blood cells, red blood cells, platelets, hemoglobin, hematocrit, mean cell volume, and mean cell hemoglobin were (7.64-22.16) x109/l, (3.69-5.47)x1012/l, (132.74-413.4) x109/l, (13.32-19.64) g/dl and (39.42-58.06)%, (91.6-113.22)fl, and (30.48-38.02)pg, respectively.Conclusion: All hematological reference interval was established from full-term newborns at University of Gondar hospital was different from other studies in Nigeria, Iraq, Pakistan, Nepal, Saudi Arabia and Iran. Therefore, own determined reference value is very important for the clinicians to correctly diagnosis the patients at health facility levels.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.