A method for measuring both dissolved ozone (DO3) concentration and UV absorbance was developed adopting ultraviolet (UV) absorption method (JWWA, 1993) using sodium thiosulfate (Na2S2O3) solution for removing residual ozone in ozonated water. A DO3 monitor based on this method was tested. This method was proven to be effective from experimental results. The performance of the monitor was examined with continuous ozonated water. As a result, the monitor performed stably during about 2 months, so that both DO3 concentration and UV absorbance in the ozonated water could be accurately measured. Therefore, the authors have proposed the new aquatic control system with this monitor for ozonation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.