To report the use of miniscleral contact lenses (MSCLs) with diameter of 14.7 mm for Asian eyes to improve vision in patients after penetrating keratoplasty (PKP) surgery. Methods: Two patients with high corneal astigmatism post-PKP were evaluated for a contact lens fitting. Visual acuity, slit lamp, and anterior segment OCT findings before and after fitted the lens of 14.7 mm diameter were recorded. Results: A Kmax of case 1 and 2 were 52.8 D and 76.9 D, respectively at the first visit. Both patients were successfully fit with MSCLs, showing adequate corneal clearance of over 250 μm with no corneal touch on OCT and sufficient limbal clearance and edge alignment. MSCLs use resulted in improved comfort and visual acuity of 20/30 or better. Conclusion: MSCLs with diameter of 14.7 mm can be considered a safe and effective option for patients with highly steep corneas post-PKP surgery in Asian eyes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.