Précis: Both Xen gel Microstent implantation and Kahook Dual Blade (KDB) goniotomy are safe and effective as stand-alone procedures, but the Xen Gel Microstent was associated with more postoperative interventions and achieved higher success at a lower intraocular pressure threshold. Purpose: To evaluate outcomes of stand-alone Xen Gel Microstent implantation compared with stand-alone KDB goniotomy for moderate to severe glaucoma. Methods: A retrospective, single-center, case-series analysis comparing outcomes of Xen Gel Microstent implantation and KDB goniotomy stand-alone cases in 75 eyes. Primary outcomes included intraocular pressure (IOP) reduction, glaucoma medication reduction, surgical success, and complications. Surgical success was defined using IOP<21 mm Hg and IOP<18 mm Hg thresholds, with or without glaucoma medications, and without further glaucoma surgery. Subjects were followed for at least 24 months after surgery. Results: Mean baseline IOP was comparable between the Xen Gel Microstent and KDB goniotomy groups (23.7±8.4 and 25.9±7.9 mm Hg, respectively, P=0.32). At 24 months after surgery, the mean IOP after Xen Gel Microstent was 14.7±3.2 mm Hg (32.7% reduction from baseline, P=0.018) and KDB goniotomy was 16.7±3.2 mm Hg (40.4% reduction from baseline, P=0.049). Although the mean IOP was significantly lower during the first month after Xen Gel Microstent implantation, no difference in mean IOP was observed between the 2 treatment groups at 24 months after surgery (P=0.416). At 24 months after surgery, the percent reduction of IOP from baseline was not significantly different between the 2 groups. The mean reduction of glaucoma medications from baseline at 24 months was 1.69 drops after Xen Gel Microstent implantation (P=.008) and 1.67 drops after KDB goniotomy (P=0.038). Postoperative complications were nonvision-threatening and were not significantly different between the 2 groups (P=0.550). Interventions not included with complications were needling performed in 21 (37%) of eyes in the Xen Gel Microstent group and Nd:YAG goniopuncture in 1 (5.6%) eye after KDB goniotomy. With an IOP threshold <21 mm Hg, surgical success was not significantly different between the 2 groups (P=0.06). At a lower IOP threshold (<18 mm Hg), surgical success was higher after Xen Gel Microstent implantation compared with KDB goniotomy (P=0.001). Conclusions: Both stand-alone Xen Gel Microstent implantation and KDB goniotomy can effectively and safely reduce IOP for moderate to severe glaucoma. The Xen Gel Microstent was associated with a higher need for postoperative interventions and achieved greater success at a lower IOP threshold.
Purpose: Our aim was to evaluate and compare the clinical outcomes after implantation of the silicone-plate (model FP7) and porous polyethylene-plate (model M4) Ahmed Glaucoma Valves. Patients and Methods: This was a prospective, multicenter, comparative series. A total of 52 eyes (52 patients) were treated with either the silicone or porous plate Ahmed Glaucoma Valve implant. Hypertensive phase was defined as intraocular pressure >21 mmHg during the first 3 months postoperatively. Success was defined as 5 mmHg ≤intraocular pressure ≤21 mmHg (with or without additional glaucoma medications), without loss of light perception and without additional glaucoma procedures. Patients were monitored for 1 year after surgery. Results: The pre-operative intraocular pressure was 29.9 ± 6.6 mmHg and 33.8 ± 10.5 in the silicone-plate and porous-plate groups, respectively (P = 0.118). At 12 months after surgery, the mean intraocular pressure was 13.6 ± 4.7 mmHg in the silicone-plate group and 17.9 ± 10.9 mmHg in the porous-plate group (P = 0.141). The mean number of glaucoma medications at 12 months was 1.64 ± 1.40 mmHg and 1.89 ± 1.54 mmHg in the silicone-and porous-plate groups, respectively (P = 0.605). Hypertensive phase was not significantly different in the two groups (50.0% of the silicone-plate and 57.7% of the porous-plate groups, P = 0.578). At 12 months after surgery, the percent success for the silicone-plate and porous-plate groups was 88.5% and 53.8%, respectively (P = 0.005). Complications were similar in the two groups. Conclusion: The porous-plate Ahmed Glaucoma Valve showed similar average intraocular pressure reduction compared with the silicone-plate model. At 12 months after surgery, there was a significantly lower success rate in the porous-plate compared with the silicone-plate group.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.