PurposeThe goal of the Developing Human Connectome Project is to acquire MRI in 1000 neonates to create a dynamic map of human brain connectivity during early development. High‐quality imaging in this cohort without sedation presents a number of technical and practical challenges.MethodsWe designed a neonatal brain imaging system (NBIS) consisting of a dedicated 32‐channel receive array coil and a positioning device that allows placement of the infant's head deep into the coil for maximum signal‐to‐noise ratio (SNR). Disturbance to the infant was minimized by using an MRI‐compatible trolley to prepare and transport the infant and by employing a slow ramp‐up and continuation of gradient noise during scanning. Scan repeats were minimized by using a restart capability for diffusion MRI and retrospective motion correction. We measured the 1) SNR gain, 2) number of infants with a completed scan protocol, and 3) number of anatomical images with no motion artifact using NBIS compared with using an adult 32‐channel head coil.ResultsThe NBIS has 2.4 times the SNR of the adult coil and 90% protocol completion rate.ConclusionThe NBIS allows advanced neonatal brain imaging techniques to be employed in neonatal brain imaging with high protocol completion rates. Magn Reson Med 78:794–804, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Purpose The goal of the Developing Human Connectome Project is to acquire MRI in 1000 neonates to create a dynamic map of human brain connectivity during early development. High‐quality imaging in this cohort without sedation presents a number of technical and practical challenges. Methods We designed a neonatal brain imaging system (NBIS) consisting of a dedicated 32‐channel receive array coil and a positioning device that allows placement of the infant's head deep into the coil for maximum signal‐to‐noise ratio (SNR). Disturbance to the infant was minimized by using an MRI‐compatible trolley to prepare and transport the infant and by employing a slow ramp‐up and continuation of gradient noise during scanning. Scan repeats were minimized by using a restart capability for diffusion MRI and retrospective motion correction. We measured the 1) SNR gain, 2) number of infants with a completed scan protocol, and 3) number of anatomical images with no motion artifact using NBIS compared with using an adult 32‐channel head coil. Results The NBIS has 2.4 times the SNR of the adult coil and 90% protocol completion rate. Conclusion The NBIS allows advanced neonatal brain imaging techniques to be employed in neonatal brain imaging with high protocol completion rates. Magn Reson Med 78:794–804, 2017. © 2016 International Society for Magnetic Resonance in Medicine
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.