Abs ract : Measurements of the surface pressure on a simplified automobile model have been performed using pressure-sensitive paint (PSP). The program was undertaken to investigate the use of commercial and in-house PSP at low speed (between 11 m/s and 92 m/s) and to find techniques to improve the measurement accuracy. A comparison of a priori and in situ calibration methods was also conducted. A linear in situ calibration or a priori methods combined with one tap pressure, correcting for bias errors, were found to provide the best accuracy. t
AeroVelo initiated the Atlas Human-Powered Helicopter Project in August 2011 to win the AHS Sikorsky Prize, which despite prior attempts had remained unclaimed for over 30 years. The Sikorsky Prize required a human-powered helicopter to sustain flight for 60 s, momentarily reach a height of 3 m, and maintain position within a 10 m × 10 m area. A configuration study was undertaken using low-fidelity aerodynamic analysis and estimated mass figures. An aerostructural optimization framework was developed for rotor design, including a novel vortex-ring aerodynamic model with included ground effect prediction, finite-element analysis including integrated composite failure analysis, and a detailed weight estimation scheme. The airframe was composed of a wire-braced truss structure, and innovative designs were developed for many of the aircraft's lightweight-focused subsystems. After initial flight testing in August 2012, experimental optimization and performance improvement led to a second testing program beginning in January 2013. Testing in 2013 led to a reduction in required power, improved understanding of structural dynamics, and control strategy. The project culminated with the successful AHS Sikorsky Prize flight on
Mid-infrared spectromicroscopy studies on biological tissue sections require accurate identification of tumor-bearing areas in histology-stained and infrared-unstained tissue sections. Concordance was achieved as follows: paired stained and unstained thin (5 microm) human brain tumor cryosections mounted on slides were scanned with a Nikon Coolscan 4000 film scanner at 4000 dpi, edited with Adobe Photoshop CS2 software, and both digital images saved. A digital tractile grid, developed in our laboratory, was overlaid onto both images. Boundaries of tumor-containing areas in stained sections were identified by light microscopy, and a digital boundary map constructed. The map was transferred onto the unstained spectromicroscopy tissue image, and finally layered onto the gridded, equisized, spectromicroscope-generated overview image prior to Fourier transform infrared spectromicroscopy. Accurate identification of tumor-bearing areas, normal brain tissue and transitional zones allowed for meaningful interpretation of respective spectral patterns in detecting subtle differences within biochemical profiles. This is the first reported method of a standardized technique for ensuring concordance in mapping of malignant tumors by mid-infrared spectromicroscopy. This technique is applicable to all biological thin tissue sections, and serves to enhance accuracy of concordance between globar- and synchrotron-light generated infrared data with that obtained by conventional light microscopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.