Cardiac magnetic resonance (CMR)-derived left ventricular (LV) global longitudinal strain (GLS) provides incremental prognostic information on various cardiovascular diseases but has not yet been investigated comprehensively in patients with Takotsubo syndrome (TS). This study evaluated the prognostic value of feature tracking (FT) GLS, tissue tracking (TT) GLS, and fast manual long axis strain (LAS) in 147 patients with TS, who underwent CMR at a median of 2 days after admission. Long-term mortality was assessed 3 years after the acute event. In contrast to LV ejection fraction and tissue characteristics, impaired FT-GLS, TT-GLS and fast manual LAS were associated with adverse outcome. The best cutoff points for the prediction of long-term mortality were similar with all three approaches: FT-GLS −11.28%, TT-GLS −11.45%, and fast manual LAS −10.86%. Long-term mortality rates were significantly higher in patients with FT-GLS > −11.28% (25.0% versus 9.8%; p = 0.029), TT-GLS > −11.45% (20.0% versus 5.4%; p = 0.016), and LAS > −10.86% (23.3% versus 6.6%; p = 0.014). However, in multivariable analysis, diabetes mellitus (p = 0.001), atrial fibrillation (p = 0.001), malignancy (p = 0.006), and physical triggers (p = 0.006) outperformed measures of myocardial strain and emerged as the strongest, independent predictors of long-term mortality in TS. In conclusion, CMR-based longitudinal strain provides valuable prognostic information in patients with TS, regardless of the utilized technique of assessment. Long-term mortality, however, is mainly determined by comorbidities.
Background Takotsubo syndrome is usually triggered by a stressful event. The type of trigger seems to influence the outcome and should therefore be considered separately. Methods and Results Patients included in the GEIST (German‐Italian‐Spanish Takotsubo) registry were categorized according to physical trigger (PT), emotional trigger (ET), and no trigger (NT) of Takotsubo syndrome. Clinical characteristics as well as outcome predictors were analyzed. Overall, 2482 patients were included. ET was detected in 910 patients (36.7%), PT in 885 patients (34.4%), and NT was observed in 717 patients (28.9%). Compared with patients with PT or NT, patients with ET were younger, less frequently men, and had a lower prevalence of comorbidities. Adverse in‐hospital events (NT: 18.8% versus PT: 27.1% versus ET: 12.1%, P <0.001) and long‐term mortality rates (NT: 14.4% versus PT: 21.6% versus ET: 8.5%, P <0.001) were significantly lower in patients with ET. Increasing age ( P <0.001), male sex ( P =0.007), diabetes ( P <0.001), malignancy ( P =0.002), and a neurological disorder ( P <0.001) were associated with a higher risk of long‐term mortality, while chest pain ( P =0.035) and treatment with angiotensin‐converting enzyme inhibitor/angiotensin receptor blocker ( P =0.027) were confirmed as independent predictors for a lower risk of long‐term mortality. Conclusions Patients with ET have better clinical conditions and a lower mortality rate. Increasing age, male sex, malignancy, a neurological disorder, chest pain, angiotensin‐converting enzyme inhibitor/angiotensin receptor blocker, and diabetes were confirmed as predictors of long‐term mortality.
Background The need for permanent pacemaker (PPM) implantation is a common complication after transcatheter aortic valve replacement (TAVR). Deep implantation position is a risk factor for PPM implantation. Thus, in the field of self-expandable (SE) transcatheter heart valves (THV) cusp overlap projection (COP) technique was implemented to reduce parallax, allowing a more precise guidance of implantation depth. Aims This meta-analysis aims to report the outcome of patients undergoing TAVR with SE THV using COP versus conventional implantation technique (CIT). Methods Systematical search in MEDLINE and EMBASE yielded five observational controlled studies comparing both implantation techniques for the SE Evolut prosthesis (Medtronic Intern. Ltd., CA, USA) and fulfilling the inclusion criteria for meta-analysis. Results Totally, 1227 patients were included, comprising 641 who underwent COP and 586 CIT TAVR. Incidence of post-procedural need for PPM implantation was significantly lower in COP group (9.8% vs 20.6%; OR = 0.43; p < 0.00001). This was accompanied by significantly higher implantation position in COP group (mean difference distance from distal end of the intraventricular portion of the THV to the non-coronary cusp (NCC): − 1.03 mm; p = 0.00001). Incidence of new-onset left bundle branch block did not differ. Regarding procedural and 30-day mortality, technical success, post-procedural aortic regurgitation, and rates of multiple device implantation, no difference between COP and CIT was found. Conclusion COP is an effective and safe implantation technique to reduce the need for a permanent pacemaker implantation during TAVR with SE Evolut prosthesis. Graphical abstract
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.