In this article we examine the methods for detecting and predicting aging related process sensor failures by analyzing the noise of the sensor output signal. The study uses data from non-differential and differential pressure transmitters used in the pressure and water level measurements of the reactor pressure vessels of units 1 and 2 of the Olkiluoto nuclear power plant in Finland. The article contains a review of the current methods for detection of sensor failures. Additionally, we present a new method for detecting changes in the sensor output signal. The method creates fingerprints of the power spectra of the sensors by using Principal Component Analysis (PCA). The changes in these fingerprints together with the measurements of the redundant sensors can be used to detect indications of some of the impending sensor failures. In the experimental study we are able to produce stable fingerprints for both the non-differential and differential pressure transmitters. Also, a potential failure in one of the differential pressure transmitters in Olkiluoto unit 2 is detected by inspecting the fingerprints and analyzing the spectral changes of the transmitter output signal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.