A prospective clinical study of the results of prosthetic ligament replacement of the ACL with the Gore-Tex polytetrafluoroethylene prosthesis was undertaken. Thirty-three (80%) of 41 patients were available at a minimum 36 month followup (mean, 48 months; range, 36 to 62). Kaplan-Meier survival analysis revealed an 82% probability of survival of the polytetrafluoroethylene ligament at the 48 month followup. When compared to the same data at a minimum 24 month followup, the results appeared to have deteriorated somewhat over time. Three possible "predictors" of failure at later followup were identified: preoperative subjective symptoms of swelling, subjective symptoms of giving way at 2 years, and an increased anterior drawer sign at 2 years.
The aim of this study was to evaluate the clinical outcome of freeze-dried compared to fresh frozen allograft tissue used as a substitute for a ruptured ACL of the knee. In addition, the incidence of any graft rejection phenomena was recorded. Forty-one patients with ACL deficient knees underwent reconstructive surgery using a patellar bone-tendon-bone allograft that had been freeze-dried (Group 1, N = 14) or fresh frozen (Group 2, N = 27). All patients underwent the same implant technique and rehabilitation program. Followup ranged from 24 to 36 months. The evaluation consisted of subjective, objective, and instrumented laxity testing (KT-1000, MEDmetric, San Diego, CA; and Genucom, FARO Medical Technologies, Inc., Montreal, Canada). There were 31 males and 10 females. Eleven (79%) patients in Group 1 thought their knee was "normal" or "improved," and 25 (93%) in Group 2 thought the same. In addition, 10 (71%) patients in Group 1 denied any "giving way," compared to 26 (96%) in Group 2. The mean Lysholm knee score in Group 1 was 86/100 (range, 22 to 100) compared to 92/100 (range, 59 to 100). Clinical examination included the Lachman test and tests for anterior drawer sign and pivot shift. Postoperatively, Group 1 patients had the following results: Lachman test--seven Grade 0, six Grade 1, one Grade 2; anterior drawer sign--eight Grade 0, five Grade 1, one Grade 2; and pivot shift--seven Grade 0, five "trace," and two "present."(ABSTRACT TRUNCATED AT 250 WORDS)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.