Determinations of different methods of measurement of uptake of 99mTc-DTPA using scintigraphy of glomerular filtration rate (GFR) were made from 29 studies on 10 healthy beagle dogs. GFR was measured by calculating the percentage dose uptake (integral method) and rate of uptake (slope method) of 99mTc-DTPA using manual kidney regions of interest (ROI) and automatic kidney and background ROIs at different time periods of the uptake phase. These results were compared using linear regression analysis to the GFR obtained from 99mTc-DTPA plasma clearance using multiple blood samples. The best correlation coefficient between percentage DTPA uptake and GFR by DTPA clearance (r = 0.84, P < 0.001) was derived from time intervals between 30s-120s with a perirenal background ROI at 1 or 2 pixels out from the kidney ROI using automatic kidney ROI at 20% threshold. With the slope method, the best correlation coefficient (r = 0.85, P < 0.001) was obtained from time intervals between 30s-peak with the background ROI at 2 pixels out from the kidney ROI using automatic ROI at 35% threshold. The offset was higher, and the correlation varied more with different ROIs and the method was unreliable at time intervals extending beyond the peak radioactivity. Manual kidney ROIs with automatic background ROIs had slightly lower correlations. With DTPA renography both integral and slope uptake method with automatic kidney and background ROIs are accurate methods to estimate the GFR, but that the integral method is much more stable to variations in ROI size and the duration of the uptake phase of the renogram.
The sources of variability in variability of scintigraphic measurements of glomerular filtration rate (GFR) have not been determined. The day to day variability of GFR was studied in 18 healthy beagle dogs. The renal uptake of 99mTc-diethylenetriaminepentaacetic acid (DTPA) of each dog was measured using a scintigraphic technique three times at intervals of 5-26 days. GFR was calculated from a regression equation relating uptake to plasma clearance, derived in our laboratory. The mean GFR was 3.97 +/- 0.72 (SD) ml/min/kg with values from 2.66 to 5.67 ml/min/kg. Analysis of variance (ANOVA) using a linear mixed model showed that most variability is a result of the dogs, less because of day to day variability and very little to the measurement variability. The repeatability coefficients for the day to day variability and measurement variability were 1.06 and 0.21 ml/min/kg respectively. The day to day variability can be caused by physiological homeostatic adjustments by the kidneys needed because of fluctuations in food and fluid intake, each dog's individual capacity to adjust, and to intrinsic errors in the measurement method. These results should be considered when using the scintigraphic method for clinical evaluation and research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.