We tested the hypothesis that a machine learning (ML) algorithm utilizing both complex echocardiographic data and clinical parameters could be used to phenogroup a heart failure (HF) cohort and identify patients with beneficial response to cardiac resynchronization therapy (CRT).
This categorization for our consensus document should not be considered as being directly similar to that used for official society guideline recommendations which apply a classification (I-III) and level of evidence (A, B, and C) to recommendations.
Background-The benefit of novel implantable cardioverter defibrillator (ICD) programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT). However, the cause of mortality reduction remains incompletely evaluated. We aimed to identify factors associated with mortality, with focus on ICD therapy and programming in the MADIT-RIT population. Methods and Results-In MADIT-RIT, 1500 patients with a primary prophylactic indication for ICD or cardiac resynchronization therapy with defibrillator were randomized to 1 of 3 different ICD programming arms: conventional programming (ventricular tachycardia zone ≥170 beats per minute), high-rate programming (ventricular tachycardia zone ≥200 beats per minute), and delayed programming (60-second delay before therapy ≥170 beats per minute). Multivariate Cox models were used to assess the influence of time-dependent appropriate and inappropriate ICD therapy (shock and antitachycardia pacing) and randomized programming arm on all-cause mortality. During an average follow-up of 1.4±0.6 years, 71 of 1500 (5%) patients died: cardiac in 40 patients (56.3%), noncardiac in 23 patients (32.4%), and unknown in 8 patients (11.3%). Appropriate shocks (hazard ratio, 6.32; 95% confidence interval, 3.13-12.75; P<0.001) and inappropriate therapy (hazard ratio, 2.61; 95% confidence interval, 1.28-5.31; P=0.01) were significantly associated with an increased mortality risk. There was no evidence of increased mortality risk in patients who experienced appropriate antitachycardia pacing only (hazard ratio, 1.02; 95% confidence interval, 0.36-2.88; P=0.98). Randomization to conventional programming was identified as an independent predictor of death when compared with patients randomized to high-rate programming (hazard ratio, 2.0; 95% confidence interval, 1.06-3.71; P=0.03). Conclusions-In MADIT-RIT, appropriate shocks, inappropriate ICD therapy, and randomization to conventional ICD programming were independently associated with an increased mortality risk. Appropriate antitachycardia pacing was not related to an adverse outcome. Clinical Trial Registration-URL: clinicaltrials.gov; Unique identifier: NCT00947310.(Circ Arrhythm Electrophysiol. 2014;7:785-792.)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.