Abstract. In June 2009, 22 spectrometers from 14 institutes measured tropospheric and stratospheric NO 2 from the ground for more than 11 days during the Cabauw Intercomparison Campaign of Nitrogen Dioxide measuring Instruments (CINDI), at Cabauw, NL (51.97 • N, 4.93 • E). All visible instruments used a common wavelength range and set of cross sections for the spectral analysis. Most of the instruments were of the multi-axis design with analysis by differential spectroscopy software (MAX-DOAS), whose nonzenith slant columns were compared by examining slopes of their least-squares straight line fits to mean values of a selection of instruments, after taking 30-min averages. Zenith slant columns near twilight were compared by fits Correspondence to: H. K. Roscoe (h.roscoe@bas.ac.uk) to interpolated values of a reference instrument, then normalised by the mean of the slopes of the best instruments. For visible MAX-DOAS instruments, the means of the fitted slopes for NO 2 and O 4 of all except one instrument were within 10% of unity at almost all non-zenith elevations, and most were within 5%. Values for UV MAX-DOAS instruments were almost as good, being 12% and 7%, respectively. For visible instruments at zenith near twilight, the means of the fitted slopes of all instruments were within 5% of unity. This level of agreement is as good as that of previous intercomparisons, despite the site not being ideal for zenith twilight measurements. It bodes well for the future of measurements of tropospheric NO 2 , as previous intercomparisons were only for zenith instruments focussing on stratospheric NO 2 , with their longer heritage.Published by Copernicus Publications on behalf of the European Geosciences Union.
Environment (RIVM) NO 2 lidar. We show that NO 2 from Multi-Axis Differential Optical Absorption Spectroscopy (MAX-DOAS) compares well with in situ measurements. We show that different MAX-DOAS instruments, operating simultaneously during the campaign, give very similar results. We also provide unique information on the spatial homogeneity and the vertical and temporal variability of NO 2 , showing that during a number of days, the NO 2 columns derived from measurements in different directions varied significantly, which implies that, under polluted conditions, measurements in one single azimuth direction are not always representative for the averaged field that the satellite observes. In addition, we show that there is good agreement between tropospheric NO 2 from OMI and MAX-DOAS, and also between total NO 2 from OMI and directsun observations. Observations of the aerosol optical thickness (AOT) show that values derived with three ground-based instruments correspond well with each other, and with aerosol optical thicknesses observed by OMI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.