The need for bone graft materials to fill bony voids or gaps that are not related to the intrinsic stability of the bone that arise due to trauma, tumors or osteolysis remains a clinically relevant and significant issue. The in vivo response of collagen–tricalcium phosphate bone graft substitutes was evaluated in a critical size cancellous defect model in skeletally mature rabbits. While the materials were chemically virtually identical, new bone formation, implant resorption and local in vivo responses were significantly different. Differences in the in vivo response may be due, in part, collagen source and processing which influences resorption profiles. Continued improvements in processing and manufacturing techniques of collagen—tricalcium phosphate bone graft substitutes can result in osteoconductive materials that support healing of critical size bone defects even in challenging pre-clinical models.
Following extensive surgical debridement in the treatment of infection, a “dead space” can result following surgical closure that can fill with hematoma, an environment conducive to bacterial growth. The eradication of dead space is essential in order to prevent recurrent infection. This study describes a novel small animal model to investigate dead-space management in muscle tissue. Two absorbable test materials were implanted in each animal; beads of calcium sulfate alone, and beads loaded with vancomycin and tobramycin. In-life blood samples and radiographs were taken from each animal following implantation. Animals were sacrificed at 1, 7, 21, 42, and 63 days post-operatively (n = 4), and implant sites were analysed by micro-computed tomography, histology and immunohistochemistry. Complete resorption was confirmed radiographically at 3 weeks post-implantation. Histologically, the host tissue response to both materials was identical, and subsequent healing at the implant sites was observed with no dead space remaining. Vancomycin was not detected in blood serum. However, peak tobramycin levels were detected in all animals at 6 hours post-implantation with no detectable levels in any animals at 72 hours post implantation. Serological inflammatory cytokine expression for IL-6, TNF-α and IL-1β indicated no unusual inflammatory response to the implanted materials or surgical procedure. The model was found to be convenient and effective for the assessment of implant materials for management of dead space in muscle tissue. The two materials tested were effective in resolving the surgically created dead space, and did not elicit any unexpected adverse host response.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.