This preliminary study aims towards the establishment of regional diagnostic reference levels (DRLs) for routine adult computed tomography (CT) examinations. The study was performed on 54 CT facilities from four African countries (Ghana, Kenya, Namibia and Senegal) and the results compared with international DRLs. Data were collected from facilities using a structured questionnaire provided by the International Atomic Energy Agency. Dose descriptors (volume computed tomography dose index [CTDIvol] and dose length product [DLP]) evaluations were performed on CT head and body phantoms for head, chest and abdomen CT examination protocols using standard methods. The estimated dose indices were compared with console-displayed dose values. Experienced radiologists accepted the diagnostic image quality of the images as per departmental imaging requirements. Median CTDIvol and DLP data from each facility were compiled to estimate the typical dose in each country. National DRLs were established based on the 75th percentile of median values, whereas the regional DRLs were based on the median of the national DRLs. Comparison of measured CTDIvol with console values of all facilities in all four countries was within 20% as recommended. The established CTDIvol DRLs for head CT, chest CT and abdomen CT were 60.9 mGy, 15.2 mGy and 15.7 mGy, respectively. Similarly, that of DLP, DRLs were 1259 mGy.cm, 544 mGy.cm and 737 mGy.cm, respectively for head CT, chest CT and abdomen CT. The established DRLs from this study were comparable to DRLs from other countries with some variations. This study would serve as baseline for establishment of a more generalized regional adult CT DRLs for Africa.
In this work, a total of twenty samples selected for investigation originate from South Africa and Namibia uranium mines. The aim of this study was to determine whether the lead ratios measured in particular samples could be used to attribute the uranium sample to the production or reprocessing plant. Measurements were carried out using an inductively coupled plasma mass spectrometer PerkinElmer NexION 2000. The precision obtained for the 208 Pb/ 206 Pb ratio, the 207 Pb/ 206 Pb ratio and the 204 Pb/ 206 Pb ratio values was considerably lower than 0.02% demonstrating the applicability of the technique for Pb isotope ratio studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.