SATIR is a new test-bed installed at Tore Supra to perform non destructive examination of actively cooled plasma facing components. Hot and cold water flow successively in the cooling tube of the component and the surface temperature is recorded with an infrared camera. Defects are detected by a slower temperature response above unbrazed areas. The connection between temperature differences and defect sizes is the main difficulty. It is established by tests of standard defects and thermal transient calculations of defective geometries. SATIR has been in use for two years and has proved to be very valuable to test industrial components as well as prototypes.
Measurements are always subject to errors resulting from the interaction of the measurement device with the quantity being measured. When dealing with electromagnetics,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.