With a short, anatomically curved intramedullary nail, we had a high rate of tibiotalocalcaneal fusion with minimal plantar neurovascular complications. We believe a short, curved intramedullary nail, with its more lateral entry point, helped maintain hindfoot alignment.
Accurate component alignment and joint line reproduction in total knee replacement (TKR) is crucial for successful clinical outcome. Advances in instrumentation and better understanding of the biomechanics can help to achieve better three dimensional alignments of TKR components and joint line restoration. We compared the accuracy of component alignment and joint line restoration with the use of 2 different TKR instrumentation kits (an older Gobot and a newer Xcelerate). Retrospective study of 150 consecutive patients undergoing primary TKR had their pre and post-operative x-rays reviewed. Seventy-five patients (group A) had their TKR using the older instrumentation kit (Gobot) and 75 (group B) had the newer version (Xcelerate). The positioning of the prosthesis components were assessed using the American Knee society radiographic evaluation method and the joint line position using the Figgie's method. The results from the two groups were statistically compared. There was a significantly greater elevation of the joint line position in TKRs done with the Gobot instrumentation (mean 4.49 mm vs. 2.71 mm in group B, P=0.03), and significant differences in the mean tibial component angle cTCA (group A 88.6°, group B 90.1°, P=0.04) and the mean Q angle (group A 6.28° valgus, group B 8.45° valgus, P=0.04). Use of the newer Xcelerate instrumentation was associated with better restoration of joint line position, however the femoral component flexion and posterior slope of the tibial component ere found to be above the desired level. Hence the overall differences between the two groups were found to be small.
Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine.
Occluding the calcar during stem insertion into cement achieves and sustains high intra-medullary pressures in both the proximal and distal femur. The highest pressures are obtained with stem insertion into Palacos-R at 4-4½ minutes after mixing, with proximal thumb occlusion. A horse-collar achieves slightly higher pressures with Simplex-P.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.