A hub-and-spoke model in South India improved STEMI care through greater use of PCI and may improve 1-year mortality. This model may serve as an example for developing STEMI systems of care in other low- to middle-income countries.
Purpose: To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. Technique: For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated with a nitinol guidewire (NGw), which is passed from the femoral artery and externalized from the left brachial artery prior to endograft delivery system introduction over a parallel stiff guidewire. Steps are then taken to remove guidewire intertwining, prevent NGw wrapping around the delivery system, and orient the LSA fenestration superiorly when the delivery system moves into the arch. Gentle traction on the ends of the NGw during endograft deployment facilitates proper fenestration alignment. A covered stent is deployed in the LSA fenestration. The technique is illustrated in a patient with congenital coarctation of the aorta and descending aortic aneurysm. For total arch repair, endograft fenestrations are made for all 3 arch branches; the left common carotid artery (LCCA) and LSA fenestrations are each cannulated with NGws, which travel together from the femoral artery, pass through a LSA snare loop, and are exteriorized from the LCCA. After endograft deployment, the innominate artery fenestration is separately cannulated using right brachial access. Placement of a parallel externalized hydrophilic guidewire passing through the LCCA fenestration (but not the LSA snare loop) and removal of the LCCA fenestration NGw allows exteriorization of the LSA fenestration NGw from the left brachial artery by pulling the LSA snare. Covered stents are deployed in all 3 fenestrations. The technique is presented in a patient with type B aortic dissection. Conclusion: Use of the precannulated fenestrated endograft system described is feasible and has the potential to make aortic arch endovascular repair simpler, more reliable, and safer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.