The objective of this study was to determine the maximum allowable initial moisture content (MC) for cross-laminated timber (CLT) walls having both exterior and interior thermal insulation. A laboratory test was conducted, for which four test walls with two different insulation solutions and two different MCs were built. Based on the test results, a simulation model was configured and simulations using the model were completed. The simulation results determined that the maximum allowable initial MC of the CLT panels was 17% for walls insulated additionally from inside with mineral wool and 15% for CLT wall assemblies insulated with polyisocyanurate (PIR). Based on these results, it was concluded that the allowable MC ranges between 8% and 16% for construction timber, and therefore, using a PIR board as interior insulation for CLT walls should be undertaken with caution given the very small margin for error in MC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.