Fracture of the distal humerus are complex and challenging injuries to treat. In this study we used distal humeral posterolateral LCP system, which is an anatomically shaped angular stable system. The purpose of this retrospective study was to evaluate clinical outcome after ORIF with posterolateral LCP plate. METHODS: 24 Consecutive patients with distal humerus fractures treated with posterolateral LCP between
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.