Though potential arc heat and blast energy from dc sources may be significant, the risk assessment for exposure to dc energy sources is often not performed because the requirement to do so is not understood. Making the task of quantifying dc arc energies more intimidating is that the professional engineer often assumes liability for any errors or omissions that may result in injury -or worse. Compounding the issue even further is that the analysis work is often based on tools, methods, and verifications for dc arc heat and blast energies that are incomplete and immature.Explained here is one approach taken to perform an arc heat and blast analysis for a research facility, specifically a concentrated load supplied by eight 1MW SCR rectifiers regulating +/-300Vdc outputs to tightly arranged terminations at a load. During the course of the research, the connections were to be reconfigured, followed by a planned retuning of the regulated dc output using hand-held multimeters at the load terminations, without wearing PPE. After assessing the risk, the research engineers were easily convinced that a full analysis needed to be performed with risk mitigation design.Index Terms -arc flash analysis, dc arc, dc arc hazard, mitigation
Although potential arc heat and blast energy from dc sources may be significant, the risk assessment for exposure to dc energy sources is often not performed because the requirement to do so is not understood. Making the task of quantifying dc arc energies more intimidating is that the professional engineer often assumes liability for any errors or omissions that may result in injury, or worse. Compounding the issue even further is that the analysis work is often based on tools, methods, and verifications for dc arc heat and blast energies that are incomplete and immature. Explained here is one approach taken to perform an arc heat and blast analysis for a research facility, specifically a concentrated load supplied by eight 1-MW silicon-controlled rectifiers regulating +/−300 Vdc outputs to tightly arranged terminations at a load. During the course of the research, the connections were to be reconfigured, followed by a planned retuning of the regulated dc output using handheld multimeters at the load terminations, without wearing personal protective equipment. After assessing the risk, the research engineers were easily convinced that a full analysis is needed to be performed with risk mitigation design.Index Terms-Arc flash analysis, dc arc, dc arc hazard, mitigation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.